US Robotics COURIER Manuale Utente Pagina 192

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 308
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 191
U.S. Robotics I-modem Command Reference
Analog Synchronous Applications • Page 16-7
Example: AT&N10%N10&W <Enter> selects a connection rate and an ofßine clock
speed of 19200 bps.
4. Choose whether the I-modem should display normal or extended synchronous result
codes.
Depending on the setting of the Xn command, the I-modem displays normal or
extended synchronous result codes. Extended result codes provide more detailed infor-
mation. DonÕt be concerned if synchronous result codes do not appear on your screenÑ
they are intended for your communications software.
By default, the I-modem is set to X1 for extended result codes. To change to normal
result codes, set the I-modem to X0.
Example: ATX1&W <Enter> selects extended result codes.
5. If the I-modem is to answer calls, enable automatic answering.
S0=0Disables Auto Answer.
S0=1Enables Auto Answer.
Example: ATS0=1&W <Enter>
Vedere la pagina 191
1 2 ... 187 188 189 190 191 192 193 194 195 196 197 ... 307 308

Commenti su questo manuale

Nessun commento