2
rev 0.0 2/13© 2013 U.S. Robotics Corporation
Network Connection:
IMPORTANT: The 10/100 Copper Aggregration Tap with TCP Resets uses a powered tapping circuit to
borrow its copy of the data so each tap NETWORK port negotiates its own connection to each end device
and then data flows throught the tap circuit from one end device to the other. Each end device MUST be set
to Auto.
IIMPORTANT: Do not exceed 90 meter maximum length between any network to network end-points
or network to monitor end-points.
● Connect the Ethernet cable of device A to the NETWORK A RJ45 port.
● Connect the Ethernet cable of device B to the NETWORK B RJ45 port.
IMPORTANT: Make sure the endpoint devices have established link before powering the tap. This
ensures that the endpoint devices are able to renegotiate link during a tap power failure.
NOTE: If a crossover cable was required before for
Rx/Tx link, then connect a crossover cable to the
port indicated in the table.
● Connect both power supplies into the rear POWER ports*. Connect the first power supply to an external
power source circuit. To assure uninterrupted monitoring connect the second power supply to a different
external power source circuit. The POWER LEDs to the left of the RJ45 ports illuminate indicating power is
on.
* Only 1 power supply is required to power the tap but plugging the second power supply into a different
power source is required for uninterrupted monitoring.
● Observe NETWORK LINK and ACT LEDs are illuminated indicating data activity.
● Connect Ethernet cables from the monitor devices to the MON 1 and MON 2 RJ45 ports.
● Observe MON 1 and 2 LEDs illuminate indicating data is passed to the monitor devices.